HOMER Pro software is the global standard for optimizing microgrid design in all sectors, from village power and island utilities to grid-connected campuses and military bases. HOMER Pro, or HOMER (Hybrid Optimization of Multiple Energy Resources), simplifies the task of evaluating designs for both off-grid and grid-connected power systems. When you design a power system, you must make many decisions about the configuration of the system, such as:
•Which components are best for this system?
•How many and what size of each component are most efficient?
The large number of technology options, variation in costs, and availability of energy resources make these decisions difficult. HOMER's optimization and sensitivity analysis algorithms make it easier to evaluate the many possible system configurations.
To use HOMER, you select and enter information under the Design button to provide the model with inputs, including components (e.g., generator, wind, and solar), component costs, and resource availability. You can also add new components, resources, and loads under the Library button.
When you click the Calculate button, HOMER uses these inputs to simulate different system configurations, or combinations of components, and generates results that you can view as a list of feasible configurations sorted by net present cost under the Results button. HOMER also displays simulation results in a wide variety of tables and graphs that help you compare configurations and evaluate them on their economic and technical merits. You can export the tables and graphs for use in reports and presentations.
You can further use the model to perform sensitivity analyses to explore the effects that changes in factors, such as resource availability and economic conditions, might have on the cost-effectiveness of different system configurations. To perform a sensitivity analysis, you provide HOMER with sensitivity values that describe a range of resource availability and component costs. HOMER simulates each system configuration using the range of values. You can use the results of a sensitivity analysis to identify the factors that have the greatest impact on the design and operation of a power system. You can also use HOMER sensitivity analysis results to answer general questions about technology options to inform planning and policy decisions.
HOMER simulates energy systems, shows system configurations optimized by cost, and provides sensitivity analyses.
HOMER simulates the operation of a system by making energy balance calculations in each time step (interval) of the year. For each time step, HOMER compares the electric and thermal demand in that time step to the energy that the system can supply in that time step, and calculates the flow of energy to and from each component of the system. For systems that include batteries or fuel-powered generators, HOMER also decides in each time step how to operate the generators and whether to charge or discharge the batteries.
HOMER performs these energy balance calculations for each system configuration that you want to consider. It then determines whether a configuration is feasible, (i.e., whether it can meet the electric demand under the conditions that you specify), and estimates the cost of installing and operating the system over the lifetime of the project. The system cost calculations account for costs such as capital, replacement, operation and maintenance, fuel, and interest.
HOMER Pro has two optimization algorithms. The original grid search algorithm simulates all of the feasible system configurations defined by the Search Space. The new HOMER Optimizer® uses a proprietary derivative-free algorithm to search for the least-costly system. HOMER then displays a list of configurations, sorted by net present cost (sometimes called life-cycle cost), that you can use to compare system design options.