Show/Hide Toolbars

HOMER Pro 3.15

Navigation: Glossary

Renewable Penetration

Scroll Prev Top Next More

HOMER Logo


 

Type:

Output Variable

Units:

none

Symbol:

pren

In every time step, HOMER calculates the renewable penetration using the following equation:

equations_p_ren

where:


 

 

Pren

= total renewable electrical power output in this time step [kW]

 

Lserved

= total electrical load served in this time step [kW]

On the Electrical tab of the Simulation Results window, HOMER reports the maximum value of renewable penetration that occurs during the year.